Let's get your machine working

DC29 Animal Purple
See all steps

Please select the appropriate option

How to clean the bin and cyclone

Remove the bin and cyclone by pressing the release catch.

Troubleshooting image

Separate the clear bin from the cyclone by pressing the catch located on the front of the bin .

Troubleshooting image

Using a dry cloth wipe the shroud.

WARNING: Do not wash the cyclone.

Troubleshooting image

Is there anything else we can help you with?

Please select the appropriate option

Test the suction from the extension tube

Remove the floor tool from the extension tube by pressing the release catch on the end of the extension tube.

Press the release catch on the extension tube to extend fully, ensuring it 'clicks' into place.

Troubleshooting image

Place your hand over the end of the extension tube and test the suction.

Is the suction at the extension tube strong or weaker than usual?

Floor tool

Flat out tool

Troubleshooting image

Turbine head

Troubleshooting image

Which floor tool are you using?

Check the floor tool

Check the floor tool openings for blockages and remove if necessary.

Troubleshooting image

Check bleed valve for blockages and remove as necessary.

Troubleshooting image

Has checking the floor tool resolved the problem?

We need a little more information to help us solve your issue.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

Check the machine for blockages

Although the suction seemed to be strong from the extension tube, there appears to be no fault with the floor tool. We therefore recommend that the rest of the machine should be checked.

Remove the hose assembly from the wand handle assembly by pressing the release clip.

Check the hose inlet

Remove the hose from the hose inlet and the front of the machine.

Troubleshooting image

Disconnect the Wand handle from the extension tube and check the extension tube for blockages.

Troubleshooting image

Checking the cyclone, bin and duct seal

Remove the cyclone from the machine and check the seal on the Main body of the machine.

Troubleshooting image

Separate the cyclone from the clear bin.

Troubleshooting image

Remove any dust or debris from the bin and check the bin seal is not missing or damaged.

Troubleshooting image

Clean the cyclone of dust and debris using a cloth or brush tool.

Check through the middle of the cyclone for any blockages and remove as necessary.

Troubleshooting image

Reassemble and test machine.

Has checking the machine for blockages resolved the problem?

Wash the filter

Please follow the steps in the video.

Has washing the filter resolved the problem?

How to wash the filter assembly

Remove the cyclone and bin from the machine and open the filter release catch.

Troubleshooting image

Remove the filter from the machine.

Troubleshooting image

Wash the filter in cold water only.

WARNING: Please do not use detergent, do not wash in a dishwasher or washing machine.

Troubleshooting image

Leave to dry in a warm place for 24 hours.

Do not dry in a tumble dryer, microwave, oven or near a naked flame.

Once fully dry replace the filter and ensure the filter cover is closed.

Troubleshooting image

Reassemble the machine

Has washing the filter resolved the problem?

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

Checking the Turbine head for blockages

Slide back the soleplate catch and undo the two soleplate fasteners, remove the soleplate from the Turbine head.

Troubleshooting image

Remove the Brush bars and clear any hair, thread and debris.

Check both of the metal shafts for blockages and ensure they rotate freely by hand.

Troubleshooting image

Check the outside surface of the plunger for fluff and debris and remove as necessary.

Troubleshooting image

Replace the two Brush bars and refit the two soleplate fasteners.

Troubleshooting image

Has checking the Turbine head resolved the problem?

Check the machine for blockages

Although the suction seemed to be strong from the extension tube, there appears to be no fault with the floor tool. We therefore recommend that the rest of the machine should be checked.

Remove the hose assembly from the wand handle assembly by pressing the release clip.

Check the hose inlet

Remove the hose from the hose inlet and the front of the machine.

Troubleshooting image

Disconnect the Wand handle from the extension tube and check the extension tube for blockages.

Troubleshooting image

Checking the cyclone, bin and duct seal

Remove the cyclone from the machine and check the seal on the Main body of the machine.

Troubleshooting image

Separate the cyclone from the clear bin.

Remove any dust or debris from the bin and check the bin seal is not missing or damaged.

Troubleshooting image

Clean the cyclone of dust and debris using a cloth or brush tool.

Check through the middle of the cyclone for any blockages and remove as necessary.

Troubleshooting image

Reassemble and test machine.

Has this resolved the problem?

Please select the appropriate option

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

When did the machine last have power?

Thermal cut out

Most Dyson vacuums have a built in safety system that stops the machine if it begins to overheat. This usually happens because the filters need washing or your machine is blocked.

Carry out the performance checks, and if your machine cuts out unplug and leave for at least 2 hours to cool down.

If the customer prefers to check the machine when the power has returned, wait for a minimum of 2 hours and ask them to call back.

Please select the appropriate option

Check the machine for blockages

Remove the hose from the hose inlet and the front of the machine.

Troubleshooting image

Disconnect the Wand handle from the extension tube and check the extension tube for blockages.

Troubleshooting image

Checking the cyclone, bin and duct seal

Remove the cyclone from the machine and check the seal on the Main body of the machine.

Troubleshooting image

Separate the cyclone from the clear bin.

Troubleshooting image

Remove any dust or debris from the bin and check the bin seal is not missing or damaged.

Troubleshooting image

Clean the cyclone of dust and debris using a cloth or brush tool.

Check through the middle of the cyclone for any blockages and remove as necessary.

Troubleshooting image

Reassemble and test machine.

Has checking for blockages resolved the problem?

Check electrical supply

Is the power cord or plug damaged?

Are the other household appliances working?

Does the vacuum work when plugged into another socket?

Has checking the electrics resolved the problem?

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

Test the suction from the extension tube

Remove the floor tool from the extension tube by pressing the release catch on the end of the extension tube.

Press the release catch on the extension tube to extend fully, ensuring it 'clicks' into place.

Troubleshooting image

Place your hand over the end of the extension tube and test the suction.

Has this resolved the problem?

Check the hose inlet

Remove the hose from the hose inlet and the front of the machine.

Troubleshooting image

Disconnect the Wand handle from the extension tube and check the extension tube for blockages.

Troubleshooting image

Checking the cyclone, bin and duct seal

Remove the cyclone from the machine and check the seal on the Main body of the machine.

Troubleshooting image

Separate the cyclone from the clear bin.

Troubleshooting image

Remove any dust or debris from the bin and check the bin seal is not missing or damaged.

Troubleshooting image

Clean the cyclone of dust and debris using a cloth or brush tool.

Check through the middle of the cyclone for any blockages and remove as necessary.

Troubleshooting image

Reassemble and test machine.

Has this resolved the problem?

Wash the filter

Please follow the steps in the video.

Has washing the filter resolved the problem?

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

How to wash the filter assembly

Remove the cyclone and bin from the machine and open the filter release catch.

Troubleshooting image

Remove the filter from the machine.

Troubleshooting image

Wash the filter in cold water only.

WARNING: Please do not use detergent, do not wash in a dishwasher or washing machine.

Troubleshooting image

Leave to dry in a warm place for 24 hours.

Do not dry in a tumble dryer, microwave, oven or near a naked flame.

Once fully dry replace the filter and ensure the filter cover is closed.

Troubleshooting image

Reassemble the machine

Has washing the filter resolved the problem?

Check the Cleaner head

If your machine is making a whistling noise, this indicates that there is a blockage or a damaged or missing seal.

Remove the floor tool from the extension tube.

Check for blockages and remove as necessary.

Troubleshooting image

Has this resolved the problem?

Check the hose inlet

Remove the hose from the hose inlet and the front of the machine.

Troubleshooting image

Disconnect the Wand handle from the extension tube and check the extension tube for blockages.

Troubleshooting image

Separate the cyclone from the clear bin.

Troubleshooting image

Remove any dust or debris from the bin and check the bin seal is not missing or damaged.

Troubleshooting image

Clean the cyclone of dust and debris using a cloth or brush tool.

Check through the middle of the cyclone for any blockages and remove as necessary.

Troubleshooting image

Reassemble and test machine.

Has this resolved the problem?

Wash the filter

Please follow the steps in the video.

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

Remove the filter

With the bin removed, pull the filter out from the top of the cyclone.

Troubleshooting image

Wash the filter

Run cold water though the open of the filter for approximately for 10 seconds.

WARNING: Do not use detergent. Do not wash in a dishwasher or washing machine.

Turn the filter upside down and tap 10 times.

Repeat until clean.

Troubleshooting image

Dry filter

Leave the filter to dry upside down in a warm place for 24 hours or until completely dry.

Troubleshooting image

Has this resolved the problem?

Cleaning the machine

A damp or musty smell is caused when dust in the cyclone has come into contact with water.

It may not be a direct contact with water, for example when vacuuming pet hair that is slightly damp, this moisture will combine with the dust in the cyclone causing the smell.

Additionally the smell may occur if the filter goes back into the machine wet.

Clean the bin and cyclone

Empty the clear bin by pressing the catch on the front, pull the bin away from the cyclone assembly.

Troubleshooting image

Using a dry cloth or combination tool clean the shroud.

Troubleshooting image

Clean the clear bin with cold water only.

WARNING: Do not use any detergents or polishes on the bin.

Has cleaning the shroud and clear bin resolved the problem?

Check the Brush bar

Slide back the soleplate catch and undo the two soleplate fasteners, remove the soleplate from the Turbine head.

Troubleshooting image

Remove the Brush bars and clear any hair, thread and debris.

Check both of the metal shafts for blockages and ensure they rotate freely by hand.

Troubleshooting image

Check the outside surface of the plunger for fluff and debris and remove as necessary.

Troubleshooting image

Replace the two Brush bars and refit the two soleplate fasteners.

Troubleshooting image

Has checking the Turbine head resolved the problem?

Using the cable

Turn off and unplug the machine.

If the cable does not rewind, firmly pull it out and fully extend it until the red tape is visible.

The cord rewind button needs to be pressed down firmly to retract the cord for storage after use. When the button is pressed down far enough you should feel and hear a click, and the cord will retract.

Has this resolved the problem?

Please call us to resolve this problem.

It looks like the Clear bin isn't working. We know how to fix it – we just can’t do it online.

One of our Dyson experts can help you get the parts or assistance you need.

Clear bin

Part no. 910897-01

Replacement clear bin for your Dyson vacuum cleaner.

€39.36

Clear bin

Clear bin

Part no. 910897-01

Replacement clear bin for your Dyson vacuum cleaner.

€39.36

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

Please call us to resolve this problem.

It looks like the Cyclone isn't working. We know how to fix it – we just can’t do it online.

One of our Dyson experts can help you get the parts or assistance you need.

Cyclone

Part no. 910885-31

Replacement cyclone for your Dyson vacuum cleaner.

€60.27

Cyclone

Part no. 910885-31

Replacement cyclone for your Dyson vacuum cleaner.

€60.27

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

You might need a replacement part.

It looks like the Hose is not working. You can solve this by ordering a new one below.

Hose

Part no. 918294-04

<p>Replacement hose for your Dyson vacuum cleaner.</p><p><span style="font-size: medium;">If you require this part please </span><span style="font-size: small;"><a href="mailto:askdyson@dyson.co.uk?subject=I%20need%20to%20order%20918294-04&amp;body=So%20that%20we%20can%20help%20you%20as%20quickly%20as%20possible,%20please%20provide%20the%20following%20information:%20%0A%0AFull%20name:%0A%0AFull%20address%20including%20postcode:%20%0A%0APhone%20number:%20%0A%0ASerial%20number:"><span style="font-size: medium;"><u>email us</u></span></a></span><span style="font-size: medium;">.</span></p>

€30.13

Hose

Hose

Part no. 918294-04

<p>Replacement hose for your Dyson vacuum cleaner.</p><p><span style="font-size: medium;">If you require this part please </span><span style="font-size: small;"><a href="mailto:askdyson@dyson.co.uk?subject=I%20need%20to%20order%20918294-04&amp;body=So%20that%20we%20can%20help%20you%20as%20quickly%20as%20possible,%20please%20provide%20the%20following%20information:%20%0A%0AFull%20name:%0A%0AFull%20address%20including%20postcode:%20%0A%0APhone%20number:%20%0A%0ASerial%20number:"><span style="font-size: medium;"><u>email us</u></span></a></span><span style="font-size: medium;">.</span></p>

€30.13

Out of stock.

€30.13

Keep me updated

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

You might need a replacement part.

It looks like the Extension tube is not working. You can solve this by ordering a new one below.

Extension tube

Part no. 917260-01

Combines with other Dyson tools to provide a longer reach.

€33.82

Extension tube

Extension tube

Part no. 917260-01

Combines with other Dyson tools to provide a longer reach.

€33.82

Out of stock.

€33.82

Keep me updated

We're glad the problem's been solved.

Please let us know if there's anything else we can help you with.

We need a little more information to help us solve your issue.

But our Customer Support Team will be able to solve your problem.

Please start a WhatsApp conversation or contact our team on 01-475-7109. If you’re using the Dyson Zone™ headphones, please contact us through our helpline or directly on Live Chat to connect with an Expert. To start a Live Chat, just click the purple icon at the bottom of the page and choose ‘Product help and support’, then select ‘Headphones support’).

If the machine is spitting out dust, this could indicate a blockage in the machine. Please proceed to the next step.

Test the suction from the extension tube

Remove the floor tool from the extension tube by pressing the release catch on the end of the extension tube.

Troubleshooting image

Press the release catch on the extension tube to extend fully, ensuring it 'clicks' into place.

Troubleshooting image

Place your hand over the end of the extension tube and test the suction.

Troubleshooting image

Is the suction from the end of the extension strong or weak?

Serial number location

The serial number can be found on the rating plate, underneath the machine, between the two wheels (e.g.: 111-UK-A11111).

Alternatively, you may find it on the Main body behind the clear bin.

Is there anything else we can help you with?

We're glad the problem's been solved.

Please let us know if there's anything else we can help you with.

Please see the attached user guide above.

Is there anything else we can help you with?

How to empty the bin

Press the release catch on the cyclone and remove the cyclone and clear bin from the machine.

Troubleshooting image

Separate the clear bin and cyclone top by pressing the bin catch on the cyclone top.

Troubleshooting image

Empty the contents of the bin into a plastic bin bag or dustbin.

Troubleshooting image

Is there anything else we can help you with?

Wash the filter

Please follow the steps in the video.

Is there anything else we can help you with?

How to wash the filter

Remove the cyclone and bin from the machine and open the filter release catch.

Troubleshooting image

Remove the filter from the machine.

Troubleshooting image

Wash the filter in cold water only.

WARNING: Please do not use detergent, do not wash in a dishwasher or washing machine.

Troubleshooting image

Leave the filter to dry in a warm place for 24 hours, until completely dry.

Do not dry the filter in a tumble dryer, microwave, oven or near a naked flame.

Troubleshooting image

Reassemble the machine.

Is there anything else we can help you with?